Hettich Knowledge Base



Results...

Knowledge Base

Category: Care & Maintenance

Topic: Decontamination

Article Title: Autoclaving

Most facilities have a pre-determined schedule of maintenance for the different categories of equipment. Hettich recommends all centrifuges be cleaned and inspected at "regular intervals". For high usage (24 hours a day/ 7 days a week), once a month is strongly suggested. For mid to low usage, (normal business hours, weekdays only), every three months.

Category: Care & Maintenance

Topic: Preventative Maintenance

Article Title: Preventative Maintenance Schedule

Most facilities have a pre-determined schedule of maintenance for the different categories of equipment. Hettich recommends cleanings and inspections of all Hettich equipment be conducted at regular intervals. For optimal results, Hettich suggests the following:

Category: Care & Maintenance

Topic: Decontamination

Article Title: Radioactive Decontamination

Hettich suggests using a cleaning agent specifically labeled as being an agent for the removal of radioactive material, as noted in the Hettich Operator's Manual.

Category: Care & Maintenance

Topic: Decontamination

Article Title: Pathogenic Decontamination

For decontamination, Hettich Instruments recommends using surface decontaminants such as “BDD” or “Bacdown” from Decon Laboratories (www.deconlabs.com). Please refer to the manufacturer’s instructions regarding the safe use of any product used for cleaning and decontamination.

Category: Care & Maintenance

Topic: Decontamination

Article Title: Decontamination Certificate

 

For the safety of transportation personnel as well as our own receiving department, a certificate of decontamination MUST accompany all products returned to Hettich Instruments.

Category: Care & Maintenance

Topic: Decontamination

Article Title: Disinfection of rotors and accessories

If infectious material should get on Hettich rotors or accessories, they must be appropriately disinfected. According to the operator’s manual, these are the most desirable ingredients of suitable disinfectants:

Category: Care & Maintenance

Topic: Preventative Maintenance

Article Title: Clean, Inspect & Lubricate

It is important to regularly clean, inspect and lubricate the rotor and accessories in all Hettich centrifuges. General maintenance procedures will ensure proper operations and extend the life span of all components, reduce the operational noise, decrease potential vibrations and prevent imbalance errors from occurring.

Category: Care & Maintenance
Topic: Preventative Maintenance
Article Title: Installing and Removing a Rotor

Centrifuge rotors are designed to sit evenly and to fit tightly onto the motor shaft. When installing a rotor, be sure that particles of dirt do not adhere to the motor shaft and cause an uneven seating of the rotor. Be sure to grease the motor shaft on a regular basis to allow for easier removal in the future and to prevent the metal of the shaft from binding with the metal of the rotor.

Category: Care & Maintenance 
Topic: Preventative Maintenance
Article Title: Lubrication of Rotor trunnions

The rotor trunnions are small steel knobs located at the end of a swing-out rotor. The centrifuge buckets hang from these trunnions during centrifugation. As the buckets swing on these trunnions, friction can build quickly due to the centrifugal forces.

Category: Care & Maintenance
Topic: Preventative Maintenance
Article Title: Maintenance and Servicing (parameters of cleaning)


With safety ALWAYS in mind, be sure to unplug the centrifuge before cleaning!

Before any other cleaning or decontamination process other than that recommended by the manufacturer is performed, the user should check with the manufacturer to make sure that the planned process does not damage the device.

Category: Care & Maintenance
Topic: Decontamination
Article Title: Radioactive Decontamination

According to the Operator’s manual, the cleaning agent used must be specifically labeled as being an agent for the removal of radioactive contaminants.

Category: Care & Maintenance
Topic: Decontamination
Article Title: Recommended Decontamination Products Radioactive:

“No Count” or “Contrad 70” from Decon Laboratories (www.deconlabs.com)

Category: Care & Maintenance
Topic: Preventative Maintenance
Article Title: Surface Cleaning and Care


The outer surfaces of Hettich centrifuges are constructed of various painted metal surfaces and molded plastics.

For the most part, these surfaces stand up to most regular cleaning products such as “409”, “Fantastic”, “Simple Green”, “Windex”, etc.